Flyer

Archivos de Medicina

  • ISSN: 1698-9465
  • Journal h-index: 29
  • Journal CiteScore: 11.20
  • Journal Impact Factor: 10.14
  • Average acceptance to publication time (5-7 days)
  • Average article processing time (30-45 days) Less than 5 volumes 30 days
    8 - 9 volumes 40 days
    10 and more volumes 45 days
Awards Nomination
Indexed In
  • Genamics JournalSeek
  • China National Knowledge Infrastructure (CNKI)
  • CiteFactor
  • Scimago
  • Electronic Journals Library
  • Directory of Research Journal Indexing (DRJI)
  • OCLC- WorldCat
  • Proquest Summons
  • University Grants Commission
  • Geneva Foundation for Medical Education and Research
  • Google Scholar
  • SHERPA ROMEO
  • Secret Search Engine Labs
Share This Page

Abstract

UTILIDAD DE LA ULTRASONOGRAFICA EN PLANO Y VISTA PARA LA CANULACI�N DE LA VENA YUGULAR INTERNA EN PACIENTES ADULTOS SOMETIDOS A CIRUG�A CARDIACA

Ramírez Muñiz Rafael Alberto, María Isabel Ruiz Romero, David Javier Montes Restrepo, Rodríguez-Rodríguez Álvaro Fe, Rodríguez-Rodríguez Alejando Alfonso and Saenz-Lopez Jose David*

Introduction: Ultrasound is a currently used tool for central venous cannulation. Short-axis (SAX) and long-axis (LAX) vision have been described for cannulation of the internal jugular vein (IJV). In our population, few studies have described its perioperative usefulness.

Objectives: characterize two ultrasound views for cannulation of the internal jugular vein in adult patients undergoing cardiac surgery in a health center in Colombia.

Methods: 25 patients were included for the SAX subgroup and 25 patients for the LAX subgroup. The following results were recorded: (1) first pass success rate (2), IJV access time, (3) identification of the anterior wall of the IJV > 50% of its diameter, (4) incidence of puncture of the posterior wall of the IJV and (5) the incidence of complications (arterial puncture, hematoma and arrhythmias).

Results: In 100% of the patients in the SAX group, success was achieved on the first attempt when punctured the IJV compared to 92% in the LAX group, without statistical significance (p=0.149). The times to access the IJV for the SAX group were 13.28 ± 2.372 seconds and for the LAX group 14.12 ± 4.256 seconds (p=0.556).

Conclusions: Of the US, SAX and LAX views, it is still not clear which is superior when compared, a larger sample is needed to achieve statistically significant results.

Published Date: 2024-04-30;